Compressed Air Audits

Our Compressed Air Audits are performed using high speed data logger designed specifically for compressed air systems. We deliver precise system information with 1 second readings over a period of 7 days for 24 hours a day.

Audit Details include:

  • Detailed System Profile with graphs of air flow, net pressure, dew point, temperature and more
  • kWh energy use based on true 3 phase kWh metering
  • Key Performance Index (kW/100CFM and kWh/100CF)
  • Motor starts / load/unload cycles
  • System Utilization
  • Education and Awareness
  • Saving Potentials

All information is provided in a detailed report with charts illustrating performance and cost data. Saving potentials are clearly identified and listed.